Arc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device Afpd

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
4 languages freely used by foreign trade staff. include: English, Spanish, Japanese, Russian
Raw-Materials Traceability
The supplier has traceability identification of raw materials
Full Customization
The supplier provides full customization services
to see all verified strength labels (22)
  • Arc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device Afpd
  • Arc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device Afpd
  • Arc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device Afpd
  • Arc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device Afpd
  • Arc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device Afpd
  • Arc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device Afpd
Find Similar Products

Basic Info.

Speed
High-Speed Circuit Breaker
Poles Number
1-4
Type
Arc Fault Circuit Breaker
Function
Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), Detection of Current Voltage and Arc
Operating Voltage
220V
Working Environment
-40~85 ºC, Humidity Less Than 90%
Installation Method
35mm DIN Rail
Features
485 Communication, Modbus-RTU ,
Display
LCD
Transport Package
Carton, Box, Wood
Specification
100x36x67, 100x72x65, 90x126x74, 72x95x66
Trademark
LEIDUN, OEM, ODM
Origin
China

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 8.00cm
Package Gross Weight
0.500kg

Product Description

Arc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device AfpdArc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device Afpd
Arc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device Afpd
An Arc Fault Circuit Breaker (AFCB), also known as an Arc Fault Detection Device (AFDD), is a specialized circuit breaker designed to identify and deactivate electrical arcs that pose a fire hazard. Unlike standard circuit breakers, which are triggered solely by overloads or short circuits, AFCB possess heightened sensitivity to detect arc faults.

Key information regarding AFCB includes the following:

Functionality:
AFCB operates by recognizing the distinct characteristics of an arc fault, which occurs when electrical current bypasses the intended load and arcs between conductors. Upon detection, the AFCB interrupts the electrical flow to prevent the potential ignition of a fire.

Regulatory Requirements:
AFCB is mandated in numerous new residential constructions and are increasingly being integrated into older homes. The specific requirements for AFCB installation are determined by the building codes applicable within the respective jurisdiction.

Troubleshooting a Tripping AFCB:
In instances where an AFCB frequently trips, it is advisable to disconnect appliances, switch off lights, and examine the wiring for any issues. Should the AFCB continue to trip despite these measures, it may indicate a malfunction or obsolescence, necessitating replacement.
  
Item Specification
Model LD-AFDD
Operating Power Supply AC 230V
Rated Frequency 50Hz
Monitoring  Alarm Alarms for fault arcs with loads below AC 63A
 
Rated Voltage AC 230V
Rated Current AC 63A and below
Dimensions 1P :36*104*75    2P:54*104*75   3P+N :72*104*75    4P:90*104*75
Mounting Method 35mm DIN rail mounting
RUN Indicator Blinks during normal operation
Rated Short-Circuit Breaking Capacity icn (KA): 4.5
Protection Class I P20
Wiring Capacity 1~25 mm2
Tripping Characteristics C,D
Electrostatic Discharge Immunity Air Discharge > 8; Contact Discharge > 6
Electrical Fast Transient/Burst Immunity 4 KA
Surge Impact Immunity 4 KA
Operating Ambient Temperature -23~+ 55ºC
Resistance to Damp Heat Class 2
Pollution Degree 2
Installation Type M Class
Altitude 2000m
Installation Environment Locations with no significant vibration and shock
 
Arc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device AfpdArc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device Afpd
Arc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device AfpdArc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device AfpdArc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device AfpdArc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device AfpdArc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device AfpdArc Fault Circuit Breaker Interrupter Afci Afdd Detector Protector Arc Fault Protective Device Afpd

 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier